SARAVEL Fan coil units are intended for individually Controlled room air conditioning in buildings. Fan coils are used in hotels, office buildings and residential complexes, whereby a central plant supplies chilled and hot water for cooling and heating.
-
7 sizes in each model
-
Heavy gage sheet metal, rugged construction
-
Long life of critical items
-
Quiet operation - whisper quiet on low speed
-
Ease of installation and maintenance
-
Decorative enclosures
-
High performance
GENERAL NOMINAL COOLING AND HEATING CAPACITY
Model |
Air flow rate (CFM) |
Water flow (gpm) |
Cooling Cap. (Btu/hr) |
Heating Cap. (Btu/hr) |
||
Cooling |
Heating |
Total |
Sensible |
|||
SF-02 |
200 |
1.6 |
2.1 |
7800 |
5300 |
20100 |
SF-03 |
300 |
2.5 |
3.1 |
12400 |
8300 |
30300 |
SF-04 |
400 |
3.2 |
4.1 |
16100 |
10800 |
39500 |
SF-06 |
600 |
4.4 |
5.8 |
21900 |
15000 |
56000 |
SF-08 |
800 |
6.0 |
7.7 |
30000 |
20300 |
74700 |
SF-10 |
1000 |
7.5 |
9.6 |
37500 |
25300 |
93500 |
SF-12 |
1200 |
9.5 |
11.8 |
47400 |
31600 |
114600 |
GENERAL PHYSICAL DATA
Unit Size |
SF-02 |
SF-03 |
SF-04 |
SF-06 |
SF-08 |
SF-10 |
SF-12 |
Face Area(sq.ft.) |
0.9 |
1.4 |
1.6 |
1.9 |
2.4 |
3.1 |
3.8 |
Number Of Fans |
1 |
2 |
2 |
2 |
3 |
4 |
4 |
Number Of Motors |
1 |
1 |
1 |
1 |
2 |
2 |
2 |
Nominal Motors HP |
1/30 |
1/25 |
1/20 |
1/20 |
1/20 |
1/20 |
1/20 |
Total Name Plate-Amps |
0.2 |
0.24 |
0.24 |
0.3 |
0.5 |
0.6 |
0.6 |
High Medium Low |
Approximate RPM |
||||||
1000 700 |
1000 700 |
1000 700 |
1000 700 |
1000 700 |
1000 700 |
1000 700 |
Note: Motor electrical characteristics are 220 V, 1 PH , 50 Cycles.
Model FE
The model FE is a front discharge exposed floor unit. All components and features are basically the same as model TE except for the discharge louver which is located in the front.
Model FC
The model FC ( Front discharge Concealed floor unit )is a concealed unit with a decorative front panel supplied by the customer in accordance with his interior design needs. The model FC is designed specifically for furred in applications, an extension collar being used to connect the discharge duct of the basic unit to the decorative grille.
DIMENSIONS
Models |
Wight (Kg) |
Dimensions |
||||||
LENGTH |
WIDTH |
HEIGHT |
||||||
FE |
FC |
FE |
FC |
FE |
FC |
FE |
FC |
|
200 |
30 |
30 |
920 |
650 |
210 |
210 |
600 |
600 |
300 |
40 |
30 |
1120 |
850 |
210 |
210 |
600 |
600 |
400 |
40 |
40 |
1220 |
950 |
210 |
210 |
600 |
600 |
600 |
50 |
40 |
1360 |
1090 |
210 |
210 |
600 |
600 |
800 |
60 |
50 |
1620 |
1350 |
210 |
210 |
600 |
600 |
1000 |
70 |
60 |
1920 |
1650 |
210 |
210 |
600 |
600 |
1200 |
80 |
80 |
2270 |
2000 |
210 |
210 |
600 |
600 |
Note: All dimensions are in mm.